法国斯耐德伺服器故障报警一览表
Number | Designation名称 | Explanation说明 |
编号 | ||
F01* | heat sink | heat sink temperature too high,limit is set |
temperature(散热器 | by manufacturer to 80°C(散热器温度太高,生产 | |
温度) | 厂规定的限值为80°C) | |
F02* | Overvoltage(电压过 | overvoltage in DC-link(直流母线电压过高) |
高) | limit depends on the mains supply voltage(限 | |
制取决于干线供电电压 | ||
F03* | following error跟踪 | message from the position controller来自位置 |
误差 | 控制器的信息 | |
F04 | feedback cable | short circuit, short to ground短路,接地短路 |
break反馈电缆断了 | ||
F05* | Undervoltage低电压 | undervoltage in DC-link直流母线电压过低 |
limit is set by manufacturer to 100V制造者将 | ||
限制设为100伏 | ||
F06 | motor temperature电 | motor temperature too high电机温度过高 |
机温度 | limit is set by manufacturer to145°C制造者将 | |
限制设为145°C | ||
F07 | aux. voltage辅助电 | internal aux. voltage not OK内部的辅助电压不 |
压 | 行 | |
F08* | Overspeed超速 | motor running away, speed is too high电机失 |
控,速度过高 | ||
F09 | EEPROM电可擦只读存 | checksum error检查和错误 |
储器 | ||
F10 | Flash-EPROM闪存 | checksum error检查和错误 |
F11 | brake 制动器 | cable break short circuit, short to ground电 |
缆断路,短路,接地短路 | ||
F12 | motor phase电机相位 | motor phase missing (cable break or similar) |
电机相位丢失(L1\L2\L3或MA、MB、MC电缆断了或类 | ||
似现象) | ||
F13* | internal | internal temperature too high内部温度过高 |
temperature内部温度 | ||
F14 | output stage输出级 | fault in the output stage输出级有故障 |
F15 | I²t max I²t最大值 | I²t max. value exceeded超过了I²t最大值,电机电 |
流过大,可能是电动缸动作时遇到较大的阻力。 | ||
F16* | supply - BTB/RTO电 | 2 or 3 phases missing in the supply feed电源 |
源- BTB/RTO | 输入过程中2或3个相位丢失 | |
F17 | A/D converter A/D | error in the analog-digital conversion, |
转换器 | usually caused by excessive EMI模拟数字转换错 | |
误,通常由过多的EMI引起 | ||
F18 | Regen 能量再生 | regen circuit faulty or incorrect setting 能 |
量再生回路有故障或设置不正确。能耗电阻连线断或 | ||
Number | Designation名称 | Explanation 说明 |
编号 | ||